Nicotine & Tobacco Research Advance Access originally published online on November 23, 2009
Nicotine & Tobacco Research 2009 11(12):1458-1466; doi:10.1093/ntr/ntp161
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Article Summary
Right arrow All Versions of this Article:
11/12/1458    most recent
ntp161v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Bernert, J. T.
Right arrow Articles by Langman, L. J.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bernert, J. T.
Right arrow Articles by Langman, L. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco 2009.

Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: A round-robin study

John T. Bernert, Peyton Jacob, III, David B. Holiday, Neal L. Benowitz, Connie S. Sosnoff, Mira V. Doig, Colin Feyerabend, Kenneth M. Aldous, Mehran Sharifi, Mark D. Kellogg and Loralie J. Langman

John T. Bernert, Ph.D., Division of Laboratory Science, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA
Peyton Jacob, III, Ph.D., Department of Medicine, University of California at San Francisco
David B. Holiday, Ph.D., RTI International, Atlanta Regional Office, Atlanta, GA
Neal L. Benowitz, M.D., Department of Medicine, University of California at San Francisco
Connie S. Sosnoff, M.S., Division of Laboratory Science, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA
Mira V. Doig, Ph.D., ABS Laboratories Ltd, Welwyn Garden City, Herts, UK
Colin Feyerabend, Ph.D., ABS Laboratories Ltd, Welwyn Garden City, Herts, UK
Kenneth M. Aldous, Ph.D., Biggs Laboratory, Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany
Mehran Sharifi, Ph.D., LabStat International ULC, Kitchener, Ontario, Canada
Mark D. Kellogg, Ph.D., Department of Laboratory Medicine, Children’s Hospital Boston, Boston, MA
Loralie J. Langman, Ph.D., Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN

Corresponding Author: John T. Bernert, Centers for Disease Control and Prevention, 4770 Buford Highway, N.E., Mailstop F-47, Atlanta, GA 30341, USA. Telephone: 770-488-7911; Fax: 770-488-0181; E-mail: jtb2{at}cdc.gov


   Abstract

Introduction: Cotinine, the primary proximate metabolite of nicotine, is commonly measured as an index of exposure to tobacco in both active users of tobacco and nonsmokers with possible exposure to secondhand smoke (SHS). A number of laboratories have implemented analyses for measuring serum cotinine in recent years, but there have been few interlaboratory comparisons of the results. Among nonsmokers exposed to SHS, the concentration of cotinine in blood can be quite low, and extensive variability in these measurements has been reported in the past.

Methods: In this study, a group of seven laboratories, all experienced in serum cotinine analysis, measured eight coded serum pools with concentrations ranging from background levels of about 0.05 ng/ml to relatively high concentrations in the active smokers range. All laboratories used either gas–liquid chromatography with nitrogen–phosphorus detection or liquid chromatography with mass spectrometric detection.

Results: All seven laboratories reliably measured the cotinine concentrations in samples that were within the range of their methods. In each case, the results for the pools were correctly ranked in order, and no significant interlaboratory bias was observed at the 5% level of significance for results from any of the pools.

Discussion: We conclude that present methods of chromatographic analysis of serum cotinine, as used by these experienced laboratories, are capable of providing accurate and precise results in both the smoker and the nonsmoker concentration range.

Received: May 6, 2009; Accepted: September 22, 2009
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.